Improved Victron Communications: High Voltage Alarm Fix: This addresses issues where high voltage alarms were triggered incorrectly in the V1 model. Improved communication should result in better monitoring and control of the battery system.
Improved Scalability: Parallel Capability: The system can now handle up to 16 batteries in parallel, compared to the previous limitation of just 4. This greatly expands the potential for energy storage, allowing for larger systems.
Upgraded Internal Components: Certified Components: The internal fuse is UL60691 certified, and the battery cells meet a range of safety and quality standards, including UL1642, UL1973, U9540A, IEC 62619:2017, and RoHS. This indicates that the battery is built to high safety standards and is suitable for various applications.
Battery UL Listing: The battery is in the process of receiving its UL Listing (a certification for safety and quality). This will further confirm its compliance with industry standards.
Improved Bluetooth App Compatibility: All-Battery Dashboard: The app now supports connecting to and monitoring all batteries from a single dashboard, even if you have up to 16 batteries in your system. This makes it easier to manage large-scale installations.
BMS Over-the-Air Firmware Updates: The system can now receive firmware updates remotely via the app. This ensures the battery management system (BMS) is always running the latest software, which can improve performance, security, and features over time.
Upgraded Battery Gauge: Better Monitoring: The new battery gauge provides more detailed information, including State of Charge (SOC), voltage, current flow, and alarm alerts. This is a significant improvement over the older version, which only had a 10-segment gauge. The added details help with better monitoring of the system's health and performance.
FEATURES:
LiFePO4 Chemistry
UL60691 Certified Internal Fuse
UL1642, UL1973, U9540A Certified Cells
IEC 62619:2017, RoHS, CE Certified Cells
Group 8D Size (20.9" x 8.7" x 12.1") L x W x H
460Ah Capacity
230A Max Continuous Discharge (500A 30s Discharge)
230A Max Continuous Charge (400A 5s Charge)
IP67 Rated, Dust and WATERPROOF
HEATED - Internal heating for below 0C charging
BLUETOOTH - iOS and Android Apps
VICTRON Communications - Parallel up to 16 together on 1 system
External Power Button & Battery Gauge INCLUDED
Built-in Smart Battery Management System (BMS)
Over charge and over discharge protection
Over current and short circuit protection
High & low temperature disconnects
3500+ Cycle life & Maintenance-free
11 Year Manufacturer Warranty
SPECIFICATIONS:
Configuration
Cell Configuration: 4S2P
Chemistry: LiFePO4
Current
Ah Capacity: 460Ah
Max Continuous Discharge Amps: 230A
Max Charge Current Amps: 230A
Max Discharge Peak Current Amps: 500A (30 Seconds) , 1300A (1 Second)
Series | Parallel: Max (4) in Series OR Max (16) in Parallel - 4S1P or 1S16P
For Use with Victron Communications, Alternator Charging, or Solar Charging:
Bulk/Absorption Voltage: 14.4V
Absorption Time: 15–30 minutes
Float Voltage: 13.6V
Equalization: Disabled
Temperature Compensation: Disabled
Charge Rate: 0.2–0.5C (92–230A)
Certifications:
UL60691, UL1642, UL1973, UL9540A, IEC62619, RoHS, CE
RECOMMENDED CHARGING SETTINGS:
To properly charge your Epoch Batteries, you will want to verify that any charging component in your system is capable of being programmed for the following specifications. Charging components can include, but are not limited to converters, inverter chargers, solar charge controllers, DC to DC chargers, etc.
Bulk/Absorption: 14.2V – 14.6V
Absorption Time: Two batteries in parallel connections require 30 minutes 200Ah
Float: 13.4V – 13.8V
Equalization: 14.4V/ Disabled
Temperature Compensation: 0/Disabled
Charge Rate: 50% of the battery or battery bank capacity
Battery Charge Temperature Range: 32°F (0°C) to 131°F (55°C)
Battery Discharge Temperature Range: -4°F (-20°C) to 140°F (60°C)
Cell Charge Temperature: 32°F (0°C) to 131°F (55°C)
NOTE: Not all chargers are capable of multistage charging. If yours is not, you will want to verify it can be programmed for the Bulk/Absorption voltage and have the other items mentioned disabled if applicable. Consult your charger's manual or the manufacturer.