🚚 Fast Delivery Times
AIMS Power Pure Sine Inverter Charger - 50A Bypass 120Vac or 240Vac - 3000 Watt
The ETL listed to UL 458 standards AIMS 3000 watt pure sine inverter charger has surpassed the ETL requirements and includes a 2 year warranty. This inverter is a a combination of an inverter, battery charger and AC auto-transfer switch into one complete system with a peak DC and AC conversion efficiency of 92%.
It is unique as the inverter will bypass 50 amps 120V or 240V (50A x2 @ 120V per leg) and outputs 120, ideal for RVs, work trucks, food trucks, and boats. It is packed with unique features and it is one of the most advanced inverter chargers on the market today. This inverter also features power factor corrected, sophisticated multi-stage charging and pure sine wave output with unprecedentedly high surge capability to meet demanding power needs of inductive loads without endangering the equipment.
The powerful battery charger is rated at 100 amps, and with power factor corrected, it uses 20-30% less energy from AC input than a standard charger, avoiding nuisance breaker trips or generator overloads. In response to the increasing demand of more advance battery charging, this model is equipped with Battery Temperature Sensing for increased charging precision. The overloads capacity is 300% of continuous output for up to 20 seconds to reliably support tools and equipment longer.
The transformers have been consistently improved for years to achieve the best balance of conversion efficiency, idle consumption and minimum THD. The idle consumption of the line is ultra-low, roughly 1.5% of its rated power.
The AC battery priority switch and auto generator start functionally making it ideal to work in either backup power or renewable energy applications.
In AC priority mode, when utility AC power cuts off, the transfer relay is de-energized and the load is automatically transferred to the inverter output. Once the qualified AC utility is restored, the relay is energized and the load is automatically transferred to AC utility.
When customized to battery priority mode via the DIP switch, the inverter will extract power from external power sources in renewable energy systems and a minimal cycle of the battery will be required. With the availability of the auto generator start, an electrical generator can be integrated into the system as a backup and started when the battery voltage goes low.
Specifications:
Specification | Value |
---|---|
Listed Standards | UL 458 |
Bypass Rating | 50 Amps |
Bypass Voltage | 120V or 240V |
Output Voltage | 120V |
Warranty | 2 years |
Continuous Output Power | 3000 Watts |
Surge Power Capability | 9000 Watts (20 seconds) |
Surge Capability (3x surge) | Yes |
Battery Priority Selector | Yes |
AC Direct Connect Terminal Block | Yes |
GFCI Rating | 20 Amps |
Marine Coated and Protected | Yes |
Multi-Stage Smart Charger | 100 Amps |
Remote Panel Availability | Yes |
Auto Gen Start | Yes |
Auto Frequency | Yes |
Typical Transfer Time | 10 milliseconds |
Battery Type Settings for Charger | 7 (Including Lithium) |
INVERTER OUTPUT | Continuous Output Power | 3000 Watts / 3KW |
Surge Rating (20 secs) | 9000 Watts / 9KW | |
Starting Electric Motor (HP) | 3 HP | |
Output Waveform | Pure Sine | |
Nominal Efficiency | >92% (Peak) | |
Line Mode Efficiency | >95% | |
Power Factor | .9 - 1 | |
Nominal Output Voltage (rms) | 120Vac | |
Output Voltage Regulation | ± 10% RMS | |
Output Frequency | 50/60 Hz ±0.3Hz | |
Short Circuit Protection | YES. Current Limit Function (fault after 1 sec) | |
Typical Transfer Time | 10ms (MAX) | |
Max THD @ Full Linear Load | <20% | |
DC INPUT | Nominal Input Voltage | 12 Vdc |
Minimum Start Voltage | 10Vdc | |
Low Battery Alarm | 10.5Vdc / 11.Vdc | |
Low Battery Trip | 10Vdc / 10.5Vdc | |
High Voltage Alarm & Fault | 16Vdc | |
High DC Input Recovery | 15.5Vdc | |
Low Battery Voltage Recover | 13Vdc | |
Sleep Mode Threshold | >50 Watts (Power Saven On) | |
CHARGE | Input Voltage Range | Narrow: 100-135Vac Wide: 90-135Vac |
Input Frequency Range | Narrow: 47-55 ±0.3Hz @ 50Hz, 57-65 ±0.3Hz @ 60Hz | |
Output Voltage | Depends on battery type | |
Charger Breaker Rating (120 Vac) | 30A | |
Max Charge Rate | 100A | |
Over Charge Protection Shutdown | 15.7V | |
Battery Type | Fast Vdc Float Vdc | |
Gel USA | 14 13.7 | |
AGM 1 | 14.1 13.4 | |
AGM 2 | 14.6 13.7 | |
Sealed Lead Acid | 14.4 13.6 | |
Gel Euro | 14.4 13.8 | |
Open Lead Acid | 14.8 13.3 | |
Lithium | 14.4 | |
De-sulphation | 15.5 for 4 hours | |
Battery Temp Sensor | YES. Part # PICGLFBATS | |
BYPASS & PROTECTION | Input Voltage Waveform | Pure sine from grid or generator |
Nominal Votage | 120Vac | |
Low Voltage Trip | 80V/100V ±4% | |
Low Voltage Re-engage | 90V/100V ±4% | |
High Voltage Trip | 140V ±4% | |
High Voltage Re-engage | 135V ±4% | |
Max Input AC Voltage | 150Vac | |
Nominal Input Frequency | 50Hz or 60Hz (auto detect) | |
Low Freq Trip | Narrow: 47 ±0.3Hz @ 50Hz, 57 ±0.3Hz @ 60Hz Wide: 40 ±0.3Hz for 50/60Hz | |
Low Freq Re-engage | Narrow: 48 ±0.3Hz @ 50Hz, 58 ±0.3Hz @ 60Hz Wide: 45 ±0.3Hz for 50/60Hz | |
High Freq Trip | Narrow: 55 ±0.3Hz @ 50Hz, 65 ±0.3Hz @ 60Hz Wide: No limit for 50/60Hz | |
High Freq Re-engage | Narrow: 54 ±0.3Hz @ 50Hz, 64 ±0.3Hz @ 60Hz Wide: No limit for 50/60Hz | |
Output Short Cirucit Protection | Circuit Breaker | |
Bypass Breaker Rating (120 Vac) | 50A | |
Bypass Breaker Rating (240 Vac) | 50A | |
GFCI Rating | 20A | |
MECHANICAL | Mounting | Predrilled holes for wall/ground |
Dimensions | 16.25"L x 11"W x 7"H | |
Weight | 58 lb | |
Shipping Dimensions | 21"H x 14"W x 12"H | |
Shipping Weight | 67 lb | |
Displays | Status LEDs/Optional LCD Remote | |
Warranty | 2 Year |